SECTION 6 - JLG CONTROL SYSTEM
6-44
– JLG Lift –
3121448
240
the digital input is open and is
managed as start-stop
hardware.
The battery charger stops the charge
until the digital input is not reclosed.
Close the digital input.
253
Network voltage higher than
the max value of the
functioning window.
The battery charger does not charge
until the network voltage re-enters the
normal functioning window.
Control if the network voltage is in
the correct functioning parameter
244
Network voltage lower than the
min value of the functioning
window.
The battery charger does not charge
until the network voltage re-enters the
normal functioning window.
Control if the network voltage is in
the correct functioning parameter
Table 6-7. BATTERY CHARGER FAULT CODES