6.10 CURRENTS
From the SERVICE menu, pressing button 5”CURRENT”
accesses the menu CURRENT to adjust the parameter
settings in order to achieved optimum machine perfor-
mance.
1. Press button 7 “SETUP”.
2. Press button 5 “PASSWORD”.
Using the remote control buttons to enter the pass-
word 1883.
NOTE: password permit to change all CURRENT Settings.
Once the correct password is accepted the display
shown “OK”.
3. Press button 9 “ESC” two times.
NOTE: Repeat the above steps if “NO” appear on the dis-
play.
4. Press button 5 “CURRENT” to enter in menu current
setting.
Use buttons 1 PREV. and 2 NEXT to scroll the vari-
ous functions.
5. Use buttons 7 UP and 8 DOWN to adjust the values.
6. Press button 3 SAVE to save
NOTE: EVERY TIME THE RAMP VALUE GETS MODIFIED
BUTTON 3 TO SAVE MUST BE PRESSED; OTH-
ERWISE THE MODIFICATION IS NOT ACTIVATE.
NOTE: Personality settings can be adjusted within the
adjustment range in order to achieve optimum
machine performance.
NOTE: Refer to Table 6.8, Time range (sec) for recom-
mended settings.