SECTION 6 - JLG CONTROL SYSTEM
6-40
– JLG Lift –
3121448
Table 6-6. INVERTER Diagnostic trouble code chart
CODE
MEANING
1
Wrong Config
Cause: Eeprom memory not configured
Solution: Contact JLG after sales dept.
8
Watch Dog
Cause: The inverter is unable to activate or turn off the electric motor
Solution: Control connections and continuity of the electric motor. If they are OK replace
the inverter
13
Eeprom KO
Cause: Hardware or Software problem in eeprom
Solution: Replace the inverter
16
Aux output KO
Cause: Electromechanical brake problem
Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.
17
Logic failure #3
Cause: Activates in case of high peak of current in the inverter.
Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.
18
Logic Failure #2
Cause: Fault in the inverter
Solution: Replace the inverter
19
Logic failure #1
Cause:
An overvoltage or a sudden voltage drop occurred.
Solution: Usually it is a temporary anomaly due to a particular working condition. In
case the anomaly persists replace the inverter.
30
VMN low
Cause: Inverter supply voltage is lower than the batteries’ one, or the connection
with the positive terminal of the battery is not correct.
Solution: Control the connection with the positive terminal of the battery. If the anomaly
persists replace the inverter.
31
VMN High
Cause: One motor phase is not correctly connected or is broken.
Solution: Control motor phases. If the anomaly persists replace the inverter.
37
Contactor closed
Cause: The relay remains closed with power to the coil disconnected.
Solution: Control the relay