JLG X23J - X700AJ Service Manual User Manual
Page 519

SECTION 6 - JLG CONTROL SYSTEM
6-30
– JLG Lift –
3121448
POSM4 A
ON
Outrigger no. 4 is in “reduced area” (or total) – the control switch is released and
“A” line is closed
OFF
Outrigger no. 4 is in “closed” position – the control switch is released and “A” line is
open
POSM4 B
ON
Outrigger no. 4 is in “reduced area” (or total) – the control switch is released and
“B” line is closed
OFF
Outrigger no. 4 is in “closed” position – the control switch is released and “B” line is
open
R.C. BASKET
ON
The remote control is in the support in basket
OFF
The remote control is not in the support in basket
INCLIN. X
1
Indicates the inclination of the machine on the X axis in degrees
INCLIN. Y
1
Indicates the inclination of the machine on the Y axis in degrees
LOAD
94
Indicates the weight in Kg in the basket
POS. 1E2 X23J - X700AJ
Only
1423
Indicates the opening of the 1 and 2 arms cylinder in tenths of a millimeter
POS. 3 X23J - X700AJ
Only
2398
Indicates the opening of the 3 arm cylinder in tenths of a millimeter
ROTATION
180
Indicates the rotation angle of the aerial part in degrees
MOTOR RPM X23J -
X700AJ Diesel Only
2200
Indicates the engine RPM
CURRENT A
34,5
Indicates the current sent to the aerial part proportional valve or to the left-side
undercarriage proportional valve
CURRENT B
45,3
Indicates the current sent to the right-side proportional valve
CURRENT C
TEMPERAT.
37,6
Indicates the temperature of the control module in C°
SUPPLY (V)
12,1
Indicates the batteries voltage, or the output voltage from the battery charger