SECTION 3 - CHASSIS & TURNTABLE
3121448
– JLG Lift –
3-119
If comparable results are not available, the following table
can be used as a guide value:
The specified values are valid for the following conditions:
• Operating temperature on the slew drive < 70° C (158°
F).
• Circumferential speed < 0.5 m/s (1.64 ft/sec) for SP
slew drives.
• Output speed < 5 rpm for WD slew drives.
• Low to moderate load.
COMPLY WITH THE INSTRUCTIONS IN THE OPER-
A T I N G M A N U A L P RO V I D E D B Y T H E M A N U F A C -
T U R E R, F O R L U B R I C A T I O N O F O P T I O N A L
I N T E R M E D I A T E G E A R U N I T S , B R A K E S , A N D
MOTORS.
I F N E C E S S A R Y R E - L U B R I C A T E P E R M A N E N T
BRAKES. FOR THIS ONLY USE THE SPECIAL GREASE
SHELL RETINAX HDX2.
Work conditions
Lubricating interval
To be executed by
Dry and clean workshop hall (rotary
tables, robots, etc.)
Approx. every 300 operating hours, at
least every 6 months
Specialist
Severe conditions on open terrain
(cranes, excavators, etc.)
Approx. every 100 to 200 operating
hours, at least every 4 months
Specialist
Aggressive climatic conditions,
(ocean, desert, arctic climate,
extremely polluted environment,
≥
70
operating hours per week
Every 50 operating hours, at least
every
2 months
Specialist
Extreme conditions (tunnel boring
machines, steel works, wind turbines)
Continuous lubrication (through cen-
tral lubrication or grease cups)
Specialist