X17j – JLG X23J - X700AJ Service Manual User Manual
Page 520

SECTION 6 - JLG CONTROL SYSTEM
3121448
– JLG Lift –
6-31
Table 6-4. Menu Input
X17J
ST1 A GND
ON
Stabiliser 1 on the ground – The switch is released and line A is closed
OFF
Stabiliser 1 raised – The switch is pressed and line A is open
ST1 B GND
ON
Stabiliser 1 on the ground – The switch is released and line B is closed
OFF
Stabiliser 1 raised – The switch is pressed and line B is open
FREE
Ignore this signal
FREE
Ignore this signal
ST2 A GND
ON
Stabiliser 2 on the ground – The switch is released and line A is closed
OFF
Stabiliser 2 raised – The switch is pressed and line A is open
ST2 B GND
ON
Stabiliser 2 on the ground – The switch is released and line B is closed
OFF
Stabiliser 2 raised – The switch is pressed and line B is open
FREE
Ignore this signal
FREE
Ignore this signal
ST3 A GND
ON
Stabiliser 3 on the ground – The switch is released and line A is closed
OFF
Stabiliser 3 raised – The switch is pressed and line A is open
ST3 B GND
ON
Stabiliser 3 on the ground – The switch is released and line B is closed
OFF
Stabiliser 3 raised – The switch is pressed and line B is open
FREE
Ignore this signal
FREE
Ignore this signal
ST4 A GND
ON
Stabiliser 4 on the ground – The switch is released and line A is closed
OFF
Stabiliser 4 raised – The switch is pressed and line A is open
ST4 B GND
ON
Stabiliser 4 on the ground – The switch is released and line B is closed
OFF
Stabiliser 4 raised – The switch is pressed and line B is open
FREE
Ignore this signal
FREE
Ignore this signal
ESSICAE A
ON
The aerial part safety devices are deactivated by the key switch (emergency
condition) – Line A of the aerial part safety bypass button is closed
OFF
The aerial part safety devices are active (normal operating condition) – Line A of
the aerial part safety bypass button is open