7-27
7.5.10 Timer 1 to 3 setting modes (SET 14, 15 and 16)
Setting data
Character
Setting (monitor) value
Initial value
Unit
Setting
value
Blind
Timer function
tMF1
tMF2
tMF3
1: Auto-start
2: Manual start
3: SV start
4: DI 1 start
5: DI 2 start
6: DI 3 start
7: DI 4 start
8: Event 1 start
9: Event 2 start
10: Event 3 start
11: Event 4 start
12: Event 5 start
13: Event 6 start
14: Event 7 start
15: Step start *1
16: Soak start *1
1
None
Unit
H/M1
H/M2
H/M3
1: Hour/minute
2: Minute/second
1
Hour/
minute/
second
Start SV permissible
range
tSV1
tSV2
tSV3
Temperature: 0.0 to 999.9
0 to 999
Analog: 0 to 9999
C
Digit
ON delay timer
oNT1
oNT2
oNT3
0:00 to 99:59
0:00
Hour/
minute/
second
OFF delay timer
oFt1
oFt2
oFt3
0:00 to 99:59
0:00
Hour/
minute/
second
Repeat count
RUN1
RUN2
RUN3
0 - 99 (infinite with 0)
1
Count
Remaining time
monitor
tIA1
tIA2
tIA3
0:00 - 99:59
Start/stop with the ▲/▼ key
0:00
Hour/
minute/
second
*1: Selectable only on Ver3.xx or later.