TOHO ELECTRONICS TTM200 User Manual
Page 230
![background image](/manuals/373640/230/background.png)
48-7009-E
6-82
■
Zone Threshold* Setting
SEt23
ZbNK
Setting Contents
Initial
Value
3
PM*
Zone Threshold* Setting 3
1200
Setting Range
SV Limiter Lower Limit (SLL) to SV Limiter
Upper Limit (SLH)
(PM*) will depend on the setting value of
bANKH
PM7 PM6~SLH
PM6 PM5~SLH
PM5 PM4~SLH
PM4 PM3~SLH
PM3 PM2~SLH
PM2 PM1~SLH
PM1 SLL~SLH
※
Setting of the Threshold is done for the Bank
Automatic Switching which will be done for *
= 1 to 7 (8 bank row).
※
When SET04 bANKH=0, the setting will be invalid.
There will be no indication either.
※ 3
Setting of the Threshold is done for the Bank Automatic Switching which will be done for the Zone
Threshold*Setting (PM1 to PM7) <Max. 8 banks>
Setting Range: SLL to SLH
Threshold can be set to max. of 7 (8 banks).
The initial value set is 1200 for PM1 to PM7. The bank switching by selected source will not be done.
NOTE: The setting range is PM*SV Limiter Lower Limit (SLL) to SV Limiter Upper Limit, but when the
value of the PM(*・1) is set exceeding the PM(*), the PM (*) will be changed together.
The selectable range of the Zone Threshold*Setting (PM*) will depend on the setting value of bANKH.
SET04
bANKH=
Selectable PM*
0 PM No Indication
1 * = 1
2 * = 1~2
3 * = 1~3
4 * = 1~4
5 * = 1~5
6 * = 1~6
7 * = 1~7
Note: the parameters indicated will vary depending on the value of SET04 BANKH.