Dial-backup number – ADTRAN 1000R Series User Manual
Page 882
![background image](/manuals/36101/882/background.png)
Command Reference Guide
Frame Relay Sub-Interface Config Command Set
61200510L1-35E
Copyright © 2005 ADTRAN
882
dial-backup number
Use the dial-backup number command to configure the phone number and the call type the router will
dial upon network failure. Multiple entries can be made for an interface to allow alternate sites to be dialed.
For more detailed information on Frame Relay dial-backup functionality, refer to the Functional Notes and
Technology Review sections of the command dial-backup call-mode [answer | answer-always | originate |
originate-answer | originate-answer-always]
.
Syntax Description
Specifies the phone numbers to call when the backup is initiated.
analog
Indicates number connects to an analog modem.
digital-56k
Indicates number belongs to a digital 56 kbps per DS0 connection.
digital-64k
Indicates number belongs to a digital 64 kbps per DS0 connection.
Specifies the minimum number of DS0s required for a digital 56 or 64 kbps
connection (Range: 1 to 24).
Specifies the maximum number of DS0s desired for a digital 56 or 64 kbps
connection (Range: 1 to 24).
Specifies the Frame Relay sub-interface (e.g., fr 3.1) to use when originating or
answering using this number.
Default Values
By default, there are no configured dial-backup numbers.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example configures the AOS to dial 704-555-1212 (digital 64 kbps connection) to initiate
dial-backup operation on this endpoint using sub-interface Frame Relay 3.1:
(config)#interface frame-relay 1.16
(config-fr 1.16)#dial-backup number 7045551212 digital-64k 1 1 fr 3.1