Garp timer [join | leave | leaveall] Page 387
Page 387

Command Reference Guide
Global Configuration Mode Command Set
61200510L1-35E
Copyright © 2005 ADTRAN
387
garp timer [join | leave | leaveall]
Use the garp timer command to adjust the timers used in all GARP applications (currently only GVRP)
on the switch.
Syntax Description
join
Specifies the time (in milliseconds) between GARP application join messages.
leave
Specifies the time (in milliseconds) between GARP application leave messages (must
be at least 3 times longer than the join timer).
leaveall
Specifies the time (in milliseconds) between GARP application leave all
messages (must be greater than the leave timer).
Specifies the timer values.
Default Values
By default, the join timer is 200 milliseconds, the leave timer is 600 milliseconds, and the leaveall timer is
10000 milliseconds.
Applicable Platforms
This command applies to the NetVanta 300, 1000, and 1000R Series units.
Command History
Release 8.1
Command was introduced.
Functional Notes
All devices communicating using GARP in the network need to have the same values for these timers.
Changing these values is not recommended.
Usage Examples
The following example specifies the time (in milliseconds) between GARP application leave all messages:
(config)#garp timer leaveall 20000