PECIFICATIONS
Interface Type:
RJ-48C
Line Rate:
1.544 Mbits/s +/- 75 bps
Capacity:
Eight T1 circuits
Line Codes:
AMI or B8ZS
Framing:
D4 (SF) or ESF
Line Build-Out:
0,- 7.5, -15, -22.5 dB
Input Signal:
0 to -36 dB (DS-1)
Support for Nx64 on all T1 interfaces (1-8)
Test:
Line loopback, payload loopback, remote
loopback, test pattern generation and detection:
QRSS, 20
20
-1, 2
15
-1, 511, all ones, all zeros
Environmental:
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: up to 95% Noncondensing
Clock Source:
Network, Internal
Compliance:
FCC Part 15/Class A, UL 60950/CSA C22.2 No.
60950, FCC Part 68/ACTA, Industry Canada
I
NSTALLATION
I
NSTRUCTIONS
1. Remove the cover plate from the appropriate option slot in the
NetVanta 4305/5305 Base Unit.
2. Slide the NetVanta Octal T1 Wide Module into the option slot until the
module is firmly positioned against the front of the chassis.
3. Secure the thumbscrews at both edges of the module. Tighten with a
screwdriver.
4. Connect the cables to the associated device(s).
5. Complete the installation of the system as specified in the Hardware
Installation Guide (P/N 61200890L1-34 or P/N 61200990L1-34).
T1 N
ETWORK
(RJ-48C) C
ONNECTION
P
INOUT
Pin
Name
Description
1
R1
Receive data from the network
2
T1
Receive data from the network
3
—
UNUSED
4
R
Transmit data toward the network
5
T
Transmit data toward the network
6-8
—
UNUSED