ADTRAN 1000R Series User Manual
Page 593
Command Reference Guide
DSX-1 Interface Configuration Command Set
61200510L1-35E
Copyright © 2005 ADTRAN
593
signaling-mode [message-oriented | none | robbed-bit]
Use the signaling-mode command to configure the signaling type (robbed-bit for voice or clear channel
for data) for the DS0s mapped to the DSX-1 port.
Syntax Description
message-oriented
Specifies clear channel signaling on Channel 24 only. Use this signaling type with
QSIG installations.
none
Specifies clear channel signaling on all 24 DS0s. Use this signaling type with
data-only or PRI DSX-1 installations.
robbed-bit
Specifies robbed bit signaling on all DS0s. Use this signaling type for voice-only
DSX-1 applications.
Default Values
By default, the signaling mode is set to robbed-bit.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, 4000, and 5000 and Total Access 900 Series units.
Command History
Release 1.1
Command was introduced.
Usage Examples
The following example configures the DSX-1 port for PRI compatibility:
(config)#interface t1 1/2
(config-t1 1/2)#signaling-mode none