ADTRAN D4 TRI-C DP User Manual

Tri-c dp / d4, Tri-c dp, Status leds

background image

TRI-C DP / D4

TRI-C DP

1102182L1

B2

B1

PTRN

L

O
G

I

C

OUT

(Rx)

IN

(Tx)

NORM

AD6

AD5

AD4

AD3

AD2

AD1

NT1

LPTX

CRTX

LPBK

TEST

LP

CR

ACT

TEST

ERR

TRI-C DP / D4

CLEI: D4D3MU0D_ _

■ For a complete Installation and Maintenance Practice: (877) 457-5007, Document # 427. Please have your fax number available. ■

STATUS LEDs

LP

OFF

TRI loop sync has been established and no Near End Block Errors

(NEBE) are being received from the loop interface

RED

TRI-interface is out of sync or there is loss of signal

YELLOW

Indicates a BER of 10

-5

has been detected

FLASHING

Flashes upon receipt of a Near End Block Error (NEBE) or when a

BER > 10

-6

is detected during Local Performance Monitoring

CR

OFF

Carrier sync (framing per TR-TSY-000397) has been established

and no Near End Block Errors are being received frrom the carrier

interface

RED

No framing pattern is being received

YELLOW

A BER > 10-5 has been detected

FLASHING

Flashes upon receipt of a Near End Block Error (NEBE) or when a

BER > 10-6 is detected during Local Performance Monitoring

ACT

GREEN

Layer 1 from the ISDN switch to the customer ISDN terminal

equipment has been established

TEST

GREEN

Unit is in Local Performance Monitoring mode or the local test

pattern gen/det in invoked

YELLOW

Front panel test has been successssfully initiated or unit is
responding to a 2B+D loopback request

FLASHING

Flashes once every two seconds when responding to a B1 loopback
request or when forced into a B1 loopback from the front panel.
Flashes twice every two seconds when responding to a B2 loopback
request or when forced into a B2 loopback from the front panel.

ERR

FLASHING

Errors detected by local test pattern detector

FACEPLATE SWITCHES

Rotary Switch - used to select circuit elements for loopback testing

AD1 – selects address of local unit for loopback

AD2 – selects address of next unit downstream for loopback

AD3 – selects address of second unit downstream for loopback

AD4 – selects address of third unit downstream for loopback

AD5 – selects address of fourth unit downstream for loopback

AD6 – selects address of fifth unit downstream for loopback

LPBK – forces this unit to set up bidirectional loopback for selected B1 or B2 channel

CRTX – sets up loopback toward carrier

LPTX – sets up loopback toward the loop

NT1 – selects address of the NT1 for loopback

TEST – initiates selected loopback test from rotary switch

DIP SWITCHES

B1/B2 – selects which B channel, B1 or B2, to be tested during local tests

NORM/PTRN – used to select whether test pattern is sent from a test set or the unit itself
NORM – test pattern is sent from test set plugged into faceplate bantam jacks
PTRN – test pattern, 2047, is internally generated and transmitted

C A U T I O N

C A U T I O N !

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

LOGIC BANTAM JACKS

Used to perform upstream and downstream testing with a DS0 level tester such
as a TPI 108/109 or Fireberd 4000/6000.

Rx (OUT) – transmits signal out to unit being tested
Tx (IN) – receives signal in from unit being tested

HARDWARE SWITCHES SW1 & SW2

SW1-1: TRM – along with SW1-2, selects the bank type for the U-BR1TE IV

SW1-2: TRM

Bank

Count/Slot

SW1-1

SW1-2

D4

D4 Counting

On

Off

D1D Counting

On

On

SLC I

CU in slots 1,4,7,10

On

On

CU in slots 2,5,8,11

Off

Off

SLC III

D4 Counting

On

On

D1D Counting

Off

On

SW1-3: B1 –along with SW4 and SW5, selects the service level

SW1-4: B2

SW1-5: D

Service Option

SW1-3

SW1-4

SW1-5

(B1)

(B2)

(D)

2B+D

On

On

On

2B

On

On

Off

B1+D

On

Off

On

B2+D

Off

On

On

B1

On

Off

Off

B2

Off

On

Off

D

Off

Off

On

SW1-6: Zero Byte Substitution (ZBS)

Enables or disables ZBS

Note: ZBS must be set the same for the COT and RT. For AMI-provisioned carriers,

ZBS should be enabled. Setting is optional for B8ZS-provisioned carriers.

COMPLIANCE

This product is intended to be installed
in products providing a Type “B” or “E”
enclosure and in restricted access location
only.

WARRANTY

Warranty for Carrier Networks products manufactured by ADTRAN and supplied
under Buyer’s order for use in the U.S. is ten (10) years. For a complete copy of
ADTRAN’s U.S. and Canada Carrier Networks Equipment Warranty, call
(877) 457-5007, Document #414.

Code

Input Output

Power Code (PC)

F

C

Telecommunication Code (TC)

X

Installation Code (IC)

A

JOB

A

ID

PRICING AND AVAILABILITY 800.827.0807

TECHNICAL SUPPORT 800.726.8663

RETURN FOR REPAIR 256.963.8722

www.adtran.com