Chapter 3: Using the CLS200

CLS200 Series User’s Guide

56

Watlow Anafaze

Doc.# 0600-3050-2000

Table 3.2 explains the control status symbols on the bot-
tom line of bar graph display. Additional symbols may ap-
pear with the ramp/soak option. See Bar Graph Display on
page 146
.

Table 3.2

Control Status Symbols on the Bar

Graph and Single Loop Displays

Navigating in Bar Graph Display

When the bar graph display is visible:

Press the

YES (up) or NO (down) key to see a new group

of loops.

Press

ENTER twice to scan all groups of loops. The

groups will display sequentially for three seconds
each. This is called scanning mode.

Press any key to stop scanning.

Press

BACK once to go to the job display, if enabled, or

the single loop display.

Bar Graph

Display

Symbol

Single

Loop

Display

Symbol

Description

M

MAN

One or both outputs are

enabled. Loop is in manual con-

trol.

A

AUTO

Only one output (heat or cool) is

enabled. Loop is in automatic

control.

T

TUNE

The loop is in autotune mode.

H
T

HEAT

Both heat and cool outputs are

enabled. Loop is in automatic

control and heating.

C
L

COOL

Both heat and cool outputs are

enabled. Loop is in automatic

control and cooling.

(blank)

(blank)

Both outputs disabled, or input

type is set to SKIP.