Chapter 5: Extruder
Doc.# 0600-3050-2000
Watlow Anafaze
109
Table 5.1 Default Control Parameters for Fan Cool Output
Table 5.2 Default Control Parameters for Oil Cool Output
Table 5.3 Default Control Parameters for H2O Cool Output
Parameter
Default Value
HEAT CONTROL PB?
50 (for J-type thermocouple) depends on Input Type setting
HEAT CONTROL TI?
500 sec/repeat
HEAT CONTROL TD?
125 sec
HEAT CONTROL FILTER
6
COOL CONTROL PB?
10 (for J-type thermocouple) depends on Input Type setting
COOL CONTROL TI?
0 sec/repeat
COOL CONTROL TD?
0 sec
COOL CONTROL FILTER?
4
Parameter
Default Value
HEAT CONTROL PB?
50 (for J-type thermocouple) depends on Input Type setting
HEAT CONTROL TI?
500 sec/repeat
HEAT CONTROL TD?
125 sec
HEAT CONTROL FILTER
6
COOL CONTROL PB?
35 (for J-type thermocouple) depends on Input Type setting
COOL CONTROL TI?
300 sec/repeat
COOL CONTROL TD?
60 sec
COOL CONTROL FILTER?
3
Parameter
Default Value
HEAT CONTROL PB?
50 (for J-type thermocouple) depends on Input Type setting
HEAT CONTRO TI?
500 sec/repeat
HEAT CONTROL TD?
125 sec
HEAT CONTROL FILTER
6
COOL CONTROL PB?
70 (for J-type thermocouple) depends on Input Type setting
COOL CONTROL TI?
500 sec/repeat
COOL CONTROL TD?
90 sec
COOL CONTROL FILTER?
2