beautypg.com

Watlow CLS200 User Manual

Page 241

background image

CLS200 Series User’s Guide

Index

Doc.# 0600-3050-2000

Watlow Anafaze

225

HEAT OUTPUT LIMIT

default value 93
description 96
location 73, 233

HEAT OUTPUT LIMIT TIME

default value 93
description 96
location 73, 233

HEAT OUTPUT RETRANS PV

description 114
location 112, 233

HEAT OUTPUT TYPE

default value 93
description 94
location 73, 233

heat output, see control outputs
HEAT RETRANS MAX INP

description 114
location 112, 233

HEAT RETRANS MAX OUT%

description 115
location 112, 233

HEAT RETRANS MIN INP

description 114
location 112, 233

HEAT RETRANS MIN OUT%

description 114
location 112, 233

HEAT T/C BRK OUT AVG

default value 93
description 97
location 73, 233

HEAT/COOL SPREAD

location 233

Heat/Cool Thermocouple Break Out 65
HI DEV ALARM OUTPUT

default value 99
description 101
location 73, 233

HI DEV ALARM TYPE

default value 99
description 101
location 73, 233

HI PROC ALARM OUTPUT

default value 99
description 100
location 73, 233

HI PROC ALARM SETPT

default value 99
description 100
location 73, 233

HI PROC ALARM TYPE

default value 99
description 100
location 73, 233

high deviation alarm, see process alarms
HP alarm code 164
humidity

controller 194
Dual DAC 207
power supply 205
Serial DAC 209

hysteresis

alarm 68

hysteresis, see spread

I

INPUT FILTER

default value 82
description 89
location 73, 233
setting before autotuning 64

input power, see power supply
INPUT PULSE SAMPLE TIME

default value 82
description 85
location 73, 233

INPUT READING OFFSET

default value 82
description 84
location 73, 233
values 85

INPUT SCALING HI PV

default value 82
description 88
location 73, 233
scaling parameters 86

INPUT SCALING HI RDG

default value 82
description 88
location 73, 233
scaling parameters 86

INPUT SCALING LO PV

default value 82
description 88
location 73, 233
scaling parameters 86

INPUT SCALING LO RDG

default value 82
description 89
location 73, 233
scaling parameters 86

INPUT TYPE

default value 82
description 83
effect on ramp/soak parameters 144
location 73, 233
values 83

INPUT UNITS

default value 82
description 84
location 73, 233

inputs

analog, see sensor inputs
current, see current inputs
digital, see digital inputs
filter 89
pulse, see pulse inputs
RTD, see RTD
scaling resistors 180–186
sensor, see sensor inputs
setup parameters 82–89
specifications 200202
thermocouple, see thermocouples
voltage, see voltage inputs
wiring, see installation

installation 11–49

alarm wiring 37
clearance 13–15, 195
communications 45–49