Index
Doc.# 0600-3050-2000
Watlow Anafaze
229
location 136, 233
Ref terminals, see reference voltage
reference voltage 32, 204
remote analog setpoint, see ratio control
repair, returning controller for 164
REPEAT CYCLES
description 144
location 136, 233
reset
external 139
integral, see integral
NO-key reset 176
RESET PROFILE 148
RESET WITH DEFAULTS 176
RESTORE PID DIGIN
default value 90
description 92
location 73, 233
RestoreAuto parameter 66
retransmit, see process variable retransmit
returning the controller 164
reverse action, see control outputs
REVERSED T/C DETECT
default value 82
description 85
location 73, 233
RFI, see noise
RMA number 164
RO alarm code 166
RS alarm code 166
RS-232, see EIA/TIA-232
RS-485, see EIA/TIA-485
RT alarm code 166
RTD
accuracy 201
offset 84
range 201
recommended type 32
resolution 201
scaling resistors 32, 183
troubleshooting 171
wiring 32
RTD open alarm 66
RTD shorted alarm 66
S
safety
external safety devices 9
output status on power up 10
symbols and signal words in this manual 2
SAVE SETUP TO JOB
CANNOT SAVE JOB 75
default value 74
description 75
location 73, 233
scaling parameters
example settings, flow sensor with 0-5 Vdc
signal 191
example settings, pressure sensor with 4-20mA
signal 190
example settings, pulse encoder 192
linear inputs 86–89
process variable retransmit 114–115
pulse inputs 86–89
scaling resistors
CLS204 and CLS208 input circuit 180
CLS216 input circuit 184
for current inputs 33, 181, 184
for RTD inputs 32, 183
for thermistor inputs 183
for voltage inputs 32, 182, 185
installing 180–186
SCSI cable 7, 9
clearance 13–14, 195
installing 27
SDAC HI VALUE
default value 93
description 95
location 233
SDAC LO VALUE
default value 93
description 95
location 233
SDAC MODE
default value 93
description 95
location 233
SEG ## EV# DO## ACTIVE STATE
description 141
location 136, 233
SEG ## EVENT # OUTPUT
description 141
location 136, 233
SEG ## TR# DI## ACTIVE STATE
description 142
location 136, 233
SEG ## TR# DI## TRIG
description 143
location 136, 233
SEG ## TRIG # INPUT NR
description 142
location 136, 233
SEGMENT ## EDIT SEG EVENTS
description 141
location 136, 233
SEGMENT ## EDIT SEG TRGGRS
description 142
location 136, 233
SEGMENT ## LAST SEGMENT
description 144
location 136, 233
SEGMENT ## SEG SETPT
description 140
location 136, 233
SEGMENT ## SEG TIME
description 140
location 136, 233
SEGMENT ## SEG TOLERANCE
description 143
location 136, 233
SENSOR FAIL CL OUTPUT
and output override feature 77
and reversed thermocouple detection 85
and thermocouple short detection 79
description 97
location 73, 233
values 97
Sensor Fail Cool Output parameter
and failed sensor alarm 65