Page 164: Running a profile

background image

Chapter 7: Ramp/Soak

CLS200 Series User’s Guide

148

Watlow Anafaze

Doc.# 0600-3050-2000

See Running a Profile on page 148 and Holding a Profile or
Continuing from Hold on page 150
for instructions on
changing the ramp/soak mode.

Assigning a Profile to a Loop

Use this parameter to assign a profile to a loop.

Selectable Values: A to Q or NONE

Assigning a Profile the First Time

To assign a profile to a loop that does not have a profile cur-
rently assigned:

1.

In the single loop display, switch to the loop you want
to assign a profile to.

2.

Press the

RAMP/SOAK key. The ASSIGN R/S PRO-

FILE parameter appears.

3.

Choose one of the available profiles and press

ENTER

- or -
press

BACK to return to single loop display without

sending profile data to the controller.

Assigning, Changing and Unassigning a Profile

To assign a new profile to a loop that already has one assigned:

1.

In the single loop display, switch to the loop in which
you want to change or unassign the profile.

2.

Press the

RAMP/SOAK key three times.

3.

Press the

NO key. You will see the RESET PROFILE

parameter. See Resetting a Profile on page 151.

4.

Press

YES then ENTER to reset the profile. You will

see the ASSIGN PROFILE parameter. See Assigning a
Profile to a Loop on page 148.

5.

Choose one of the available profiles or NONE (to
unassign) and press

ENTER.

6.

To return to the single loop display without changing
the profile assignments, press

BACK.

Running a Profile

When you assign a profile, it does not start running imme-
diately. Instead, the loop is in the START mode and the

ALARM

01 ASSIGN R/S
PROFILE? A