beautypg.com

Extron Electronics SME 100 User Guide User Manual

Page 82

background image

On the donor SME 100 (device D):

1.

Complete the procedure "Backing Up the SME 100 using Backup All" on the previous
page. If Backup All has already been completed, go to step 2.

2.

Open a web-browser. Enter the IP address of device D, then press .

3.

Go to the File Management Tab (see

figure 68

on page 74).

4.

Select the

File Management

link on the left sidebar of the File Management page.

5.

Select the

nortxe-backup

directory, then select the

BOX.CFG

file.

6.

Save the

BOX.CFG

file to a remote location such as a flash drive or network location (see

"Saving Files"

on page 72).

On the SME 100 to be restored (device A):

7.

Complete the procedure "Backing Up the SME 100 using Backup All" .
If Backup All has already been completed, go to step 8.

8.

In the web browser address line, enter the IP address of device A and press .

9.

Go to the File Management Tab.

10.

Select the

File Management

link on the left sidebar of the File Management page.

11.

Click the

nortxe-backup

directory

12.

Using the SME 100 file management page, locate and select the

BOX.CFG

file from

device D saved in step 6.

13.

Select

Upload

. When asked to replace the current file, choose

Yes

.

14.

Once the file is uploaded, select

Backup/Restore

from the left hand column of the File

Management page.

15.

Under Restore, select

Box-Specific

. The restore begins automatically.

16.

When the restore has completed, the SME 100 automatically reboots and the browser
returns to the Live View page.
The restore is complete. Your box now has the same configuration as the donor box.

NOTE: The

IP.CFG

file is provided as a means of restoring each box to a known

IP configuration. Although an

IP.CFG

file from one box can be uploaded to

another, it is not recommended. The file is meant as a backup for its specific
box to resolve network issues.
If there is a need to upload an

IP.CFG

file from a donor box, your box will

initially have the IP address of the donor box. Before communicating with your
box, ensure the donor box is either disconnected from the network or its power
removed; then use the donor IP address to communicate with your box. Once
connected to your box, change its IP address to the desired one.
To reference the IP settings of the donor box, look at its front panel display.

SME 100 • Web-based User Interface Operation