Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Reset all device
settings to factory
default
E ZXXX }
Zpx ]
Reset all settings and
adjustments to factory
default. Excludes IP settings
such as IP address, subnet
mask, gateway IP address, and
so on. Files on the unit are also
preserved.
Absolute system
reset
E ZQQQ }
Zpq ]
Reset all settings and
adjustments to factory
default, the IP address to
192.168.254.254
, and the
subnet mask to
255.255.0.0
.
Firmware version is preserved.
Absolute system
reset
(network settings are
retained)
E ZY }
Zpy ]
This reset is same as ZQQQ
except it excludes network
settings such as IP address,
subnet mask, gateway IP
address, unit name, DHCP
setting, and port mapping
(telnet, web, and direct
access) in order to preserve
communication with the
device. Files and passwords
are erased.
This reset is
recommended after a
firmware update.
IP system reset
E 1ZQQQ }
Zpq1 ]
This resets network settings
such as IP address, subnet
mask, gateway IP address, unit
name, DHCP setting, and port
mapping (all ports) to factory
defaults.
Encoder system
reset
E ZEEE }
Zpe ]
This resets encoder specific
settings which include video
bit rate max, frame rate,
stream mode, bit rate control,
video bit rate target, bit rate
priority, GOP length, streaming
method, streaming presets,
output size and position,
destination port, TTL, RTP and
RTSP transport protocols.
Reboot
E 1BOOT }
Boot1 ]
Reboot the SME 100.
Restart network
E 2BOOT }
Boot2 ]
Restart the network.
SME 100 • Remote Communication and Control