Command

ASCII Command
(host to unit)

Response
(unit to host)

Additional Description

IP Setup Commands
Set unit name

E X11@ CN }

Ipn

X11@ ]

Set the name of the unit.

Set unit name to
factory default

E

CN }

Ipn

X14( ]

Sets the name of the unit to the
factory default.

View unit name

E CN }

X11@ ]

View the name of the unit.

Set date / time

E X11# CT }

Ipt

X11# ]

Set the date and time.

View date / time

E CT }

X11# ]

View the date and time.

Set GMT offset

E X10# CZ }

Ipz X10# ]

Set the Greenwich Mean Time
(GMT) offset value.

View GMT offset

E CZ }

X10# ]

View the Greenwich Mean
Time (GMT) offset value.

Set daylight savings
time

E X13$ CX }

Ipx X13$ ]

Set daylight savings time.

View daylight savings
time

E CX }

X13$ ]

View the daylight savings time
setting.

Set DHCP on

E 1DH }

Idh1 ]

Sets DHCP to on.

Set DHCP off

E 0DH }

Idh0 ]

Sets DHCP to off and resets
the IP address of the
SME 100 to factory default
(192.168.254.254) if DHCP
was previously on.

View DHCP mode

E DH }

X1) ]

View the DHCP mode setting.

Set IP address

E X11$ CI }

Ipi

X11$ ]

Set the IP address of the unit.

View IP address

E CI }

X11$ ]

View the IP address of the unit.

View hardware MAC
address

E CH }

X11* ]

In verbose mode:

Iph

X11* ]

View the hardware MAC
address of the unit.

Set subnet mask

E X11( CS }

Ips

X11( ]

Set the subnet mask of the
unit.

View subnet mask

E CS }

X11( ]

View the subnet mask of the
unit.

Set gateway IP
address

E X11$ CG }

Ipg

X11$ ]

Set the gateway IP address.

View gateway IP
address

E CG }

X11$ ]

View the gateway IP address.

NOTES:

X1) = Off (disable) and On (enable)

0 = Off or disable, 1 = On or enable

X10#

= GMT offset value

-12:00 through 14:00; represents GMT offset (HH:MM)

X11@

= Unit name

Text string up to 24 characters (see

Unit name

on page 130)

X11#

= Set / view local time

Format to set: MM / DD / YY - HH : MM : SS (use the 24-hour clock)

X11$

= IP address (xxx.xxx.xxx.xxx)

Factory default IP address = 192.168.254.254

Factory default gateway IP address = 0.0.0.0

X11*

= Hardware MAC address

00 - 05 - A6 - xx - xx - xx

X11(

= Subnet mask

Factory default subnet mask = 255.255.0.0

X13$

= Daylight savings time

0 through 3 (see

Daylight savings time

on page 132)

X14(

= Default name

Shows the default name of the unit using the model name and the last

three pairs of the MAC address (example: SME - 100 - HD / SD - 00 - 02 - 3D)

SME 100 • Remote Communication and Control