Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
IP Setup Commands
Set unit name
E X11@ CN }
Ipn
•
X11@ ]
Set the name of the unit.
Set unit name to
factory default
E
•
CN }
Ipn
•
X14( ]
Sets the name of the unit to the
factory default.
View unit name
E CN }
X11@ ]
View the name of the unit.
Set date / time
E X11# CT }
Ipt
•
X11# ]
Set the date and time.
View date / time
E CT }
X11# ]
View the date and time.
Set GMT offset
E X10# CZ }
Ipz X10# ]
Set the Greenwich Mean Time
(GMT) offset value.
View GMT offset
E CZ }
X10# ]
View the Greenwich Mean
Time (GMT) offset value.
Set daylight savings
time
E X13$ CX }
Ipx X13$ ]
Set daylight savings time.
View daylight savings
time
E CX }
X13$ ]
View the daylight savings time
setting.
Set DHCP on
E 1DH }
Idh1 ]
Sets DHCP to on.
Set DHCP off
E 0DH }
Idh0 ]
Sets DHCP to off and resets
the IP address of the
SME 100 to factory default
(192.168.254.254) if DHCP
was previously on.
View DHCP mode
E DH }
X1) ]
View the DHCP mode setting.
Set IP address
E X11$ CI }
Ipi
•
X11$ ]
Set the IP address of the unit.
View IP address
E CI }
X11$ ]
View the IP address of the unit.
View hardware MAC
address
E CH }
X11* ]
In verbose mode:
Iph
•
X11* ]
View the hardware MAC
address of the unit.
Set subnet mask
E X11( CS }
Ips
•
X11( ]
Set the subnet mask of the
unit.
View subnet mask
E CS }
X11( ]
View the subnet mask of the
unit.
Set gateway IP
address
E X11$ CG }
Ipg
•
X11$ ]
Set the gateway IP address.
View gateway IP
address
E CG }
X11$ ]
View the gateway IP address.
NOTES:
X1) = Off (disable) and On (enable)
0 = Off or disable, 1 = On or enable
X10#
= GMT offset value
-12:00 through 14:00; represents GMT offset (HH:MM)
X11@
= Unit name
Text string up to 24 characters (see
Unit name
on page 130)
X11#
= Set / view local time
Format to set: MM / DD / YY - HH : MM : SS (use the 24-hour clock)
X11$
= IP address (xxx.xxx.xxx.xxx)
Factory default IP address = 192.168.254.254
Factory default gateway IP address = 0.0.0.0
X11*
= Hardware MAC address
00 - 05 - A6 - xx - xx - xx
X11(
= Subnet mask
Factory default subnet mask = 255.255.0.0
X13$
= Daylight savings time
0 through 3 (see
on page 132)
X14(
= Default name
Shows the default name of the unit using the model name and the last
three pairs of the MAC address (example: SME - 100 - HD / SD - 00 - 02 - 3D)