Extron Electronics SME 100 User Guide User Manual
Page 156

Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
User, Password, and Security Settings
NOTES:
•
For the
CA
and
CU
commands, X14! responds with 4 asterisks (
****
) if a password exists. If no password
exists, a blank response is received.
•
NSEC
= Enable / disable network security (default = off / disabled). When enabled, port 23 (telnet) will be
automatically disabled (expecting users to use SSH instead). When disabled, broadcast mode, device
manager mode, and ARP Ping mode is not available.
•
SSEC
= Enable / disable serial port security (default = off / disabled). When serial port security is enabled, a
user name and password is required to access the serial port.
Set administrator
password
E X13# CA }
Ipa
•
X14! ]
Sets the administrator
password.
Clear administrator
password
E
•
CA }
Ipa
•
]
Clears the administrator
password.
View administrator
password
E CA }
X14! ]
View the administrator
password.
Set user password
E X13# CU }
Ipu
•
X14! ]
Sets the user password.
Clear user password
E
•
CU }
Ipu
•
]
Clears the user password.
View user password
E CU }
X14! ]
View the user password.
Query security level
of a session
E CK }
X15@ ]
In verbose mode:
Pvl X15@ ]
View the security level of a
session.
Set network security
E X1) NSEC }
Nsec X1) ]
Set network security to X1).
View network
security
E NSEC }
X1) ]
View the network security.
Set serial port
security
E X1) SSEC }
Ssec X1) ]
Set the serial port security to
X1).
View serial port
security
E SSEC }
X1) ]
View the serial port security.
Log off user
E
[session#]LOFF }
Loff[session#]]
Logs off the selected session
(user). Returns the
E13
error
if the session does not exist.
Returns the
E24
error if not
authorized.
Log off self
E LOFF }
Loff[session#]]
Logs off self.
View all user sessions E XWHO }
[Session 1 record]]
[Session 2 record]]
[Session N record]]
[# of active users]
Active Users ]]
View all user sessions. Double
CR/LF (carriage return/line
feed) marks the end of the
report.
NOTES:
X1)
= Off (disable) and On (enable)
0 = Off or disable, 1 = On or enable
X13#
= Password
on page 131)
X14!
= Check password
X15@
= Connection security level
0 through 12 (see
SME 100 • Remote Communication and Control
150