Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Audio bit rate
Set audio bit rate
E A X6$ BITR }
Bitr A X6$ ]
Set the audio bit rate value of
the output to X6$.
View
E A BITR }
X6$ ]
View the currently set output
bit rate separated values.
Audio sample rate
Set sample rate
E X6% AUSR }
Ausr X6% ]
Set the audio sample rate value
of the output to X6%.
View
E AUSR }
X6% ]
View the currently set sample
rate value.
Advanced Configurations
Test pattern
Select test pattern
E X2) TEST}
Test X2) ]
Set the test pattern to X2).
View
E TEST }
X2) ]
View the current test pattern.
Input aspect ratio
Set to fill
E X! *1 ASPR}
Aspr X! *1 ]
Set input X! to always fill the
entire output raster (default).
Set to follow
E X! *2 ASPR}
Aspr X! *2 ]
Set input X! to correctly setup
each input rate with its native
aspect ratio.
View
E X! ASPR}
X3( ]
View the currently set aspect
ratio for input X!.
Power save mode
Set power save
mode
E X4) PSAV}
Psav X4) ]
Enable or disable the power
save mode.
View
E PSAV }
X4) ]
View the currently set power
save mode.
Overscan mode: applies only to SMPTE (480p – 1080p) input rates
Set overscan mode
E X#*X7^ OSCN }
Oscn X#*X7^ ]
Set input video format X# to
overscan mode X7^.
View
E X# OSCN}
X7^ ]
View the currently set overscan
mode for the input video format
X#.
NOTES:
X!
= Input selection
1 through 3 (2 and 3 applicable for EDID only)
X#
= Input video format
1 through 7, 9, 11 (see
X2)
= Test pattern
0 through 15 (see
X3(
= Aspect ratio settings
1 = Fill (default), 2 = Follow
X4)
= Power save mode
0 = Power save mode disabled (default), 1 = Power save mode enabled
X6$
= Audio bit rate (kbps)
16 through 384 (default = 384)
X6%
= Audio sample rate
3 = 48 kHz (default)
X7^
= Overscan
0 through 2 (see
Overscan
on page 130)