Simple instruction set (sis™) control, Host-to-sme 100 communications, Sme 100-initiated messages – Extron Electronics SME 100 User Guide User Manual
Page 130: For information on sis commands, see the, Simple instruction set (sis), Control
Simple Instruction Set (SIS™) Control
Host-to-SME 100 Communications
SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command sequence. When a command is valid, the SME 100
executes the command and sends a response to the host device. All responses from the
SME 100 to the host end with a carriage return and a line feed (CR/LF =
]
), which signals
the end of the response character string. A string is one or more characters.
SIS commands are sent to the SME 100 using the following programs.
•
DataViewer (see "
" on page 118)
•
Telnet (see the "
" section on page 123)
SME 100-initiated Messages
When a local event such as a front panel selection or adjustment takes place, the SME 100
responds by sending a message to the host. No response is required from the host. The
initial message sent by the SME 100 is listed here.
(c) Copyright 2011, Extron Electronics, SME 100 HD/SD, Vx.xx,
60-1061-0x]
Day, DD MMM YYYY HH:MM:SS]
Example:
(c) Copyright 2011, Extron Electronics, SME 100 HD/SD, V1.00,
60-1061-0x
Tue, 14 Jun 2011 16:51:57
The SME 100 initiates the copyright message when powered on or when connection via
Internet protocol (TCP/IP) is established. Vx.xx is the firmware version number.
NOTES:
•
A
Password
prompt appears if a password has been set on the SME 100 for the
admin and user profiles. Enter the necessary password followed by a carriage
return.
•
The
Password
prompt is repeated when an incorrect password is entered.
•
When a correct password is entered, the SME 100 responds with
Login Administrator
or
Login User
depending on the password entered.
•
If the passwords are the same for the
admin and user profiles, the user is logged in
as an administrator.
SME 100 • Remote Communication and Control
124