beautypg.com

Extron Electronics SME 100 User Guide User Manual

Page 100

background image

Universal OSD Configuration panel
This portion of the advanced configuration panel is used to configure the information
that is seen when viewing the universal OSD test pattern / label. The universal OSD
test pattern / label is an on-screen label that appears as small white text that is placed
on a black background in the top left corner of the output display window. The

table

below and on the next page lists the status information that can be selected in the

Information

drop-down menus.

NOTE: The display text and each selected status information is separated with

a comma. A maximum of 40 characters are shown when the universal OSD test
pattern / label is enabled. If the display text and the selected status information
exceeds 40 characters, the extra characters will not be shown.

Display Text — Use this field to specify the name that is seen at the beginning of
the OSD test pattern / label (20 characters maximum).

Information 1 — Use this drop-down menu to select the status information that is
displayed after the name specified in the

Display Text

field.

Information 2 — Use this drop-down menu to select the status information that is
displayed after the status information selected in the

Information 1

drop-down

menu.

Information 3 — Use this drop-down menu to select the status information that is
displayed after the status information selected in the

Information 2

drop-down

menu.

Input Type Information
Abbreviation

Description

Abbreviation

Description

Typ1

RGB

Typ5

S-Video

Typ2

YUVp / HDTV

Typ6

Composite

Typ3

RGBcvS

Typ9

DVI

Typ4

YUVi

Typ11

Autodetect

Selectable Status Information
Status Information Description

Off

No status information is displayed.

Info

The selected input (

In1

,

In2

, or

In3

), input type (see table

below), average bit rate (AVB), and current frame rate (CFR) are
displayed.

Model

The model name is displayed.

Product

The product description is displayed

System Memory

System memory information for the SME 100 is displayed. The
first number displays the amount memory (in megabytes) that
the SME 100 is currently using. The second number displays
the total amount of memory (in megabytes) on the SME 100.

User Memory

User memory information for the SME 100 is displayed. The
first number displays the amount of memory (in megabytes) that
is being used for storage on the SME 100. The second number
displays the total amount of storage memory (in megabytes) on
the SME 100.

SME 100 • Web-based Configuration Page