Extron Electronics SME 100 User Guide User Manual
Page 143
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Vertical shift
Specify a value
E X1^ VCTR }
Vctr X!*X1^ ]
Set vertical centering to X1^.
Increment value
E + VCTR }
Vctr X!*X1^ ]
Shift window down.
Decrement value
E − VCTR }
Vctr X!*X1^ ]
Shift window up.
View
E VCTR }
X1^ ]
View current setting.
Horizontal size
Specify a value
E X1& HSIZ }
Hsiz X!*X1& ]
Set horizontal size (width) to
X1&.
Increment value
E + HSIZ }
Hsiz X!*X1& ]
Increase the width of the
window.
Decrement value
E − HSIZ }
Hsiz X!*X1& ]
Decrease the width of the
window.
View
E HSIZ }
X1& ]
View current setting.
Vertical size
Specify a value
E X1& VSIZ }
Vsiz X!*X1& ]
Set vertical size (height) to X1&.
Increment value
E + VSIZ }
Vsiz X!*X1& ]
Increase the height of the
window.
Decrement value
E − VSIZ }
Vsiz X!*X1& ]
Decrease the height of the
window.
View
E VSIZ }
X1& ]
View current setting.
Horizontal zoom
Specify a value
E X1* ZOOM }
Zoom X!*X1* ]
Set zoom percentage to X1*.
Zoom in
E + ZOOM }
Zoom X!*X1* ]
Zoom in making the window
larger.
Zoom out
E − ZOOM }
Zoom X!*X1* ]
Zoom out making the window
smaller.
View
E ZOOM }
X1* ]
View current setting.
NOTES:
X!
= Input selection
1 through 3 (2 and 3 applicable for EDID only)
X1^
= Horizontal and Vertical position
Default range depends on output resolution
X1&
= Horizontal and Vertical size
Default range depends on output resolution
X1*
= Zoom
Default range depends on output resolution (default = 100%)
SME 100 • Remote Communication and Control