beautypg.com

Extron Electronics SME 100 User Guide User Manual

Page 141

background image

Command

ASCII Command
(host to unit)

Response
(unit to host)

Additional Description

Pixel phase (available only for RGB and YUVp input signals)
Specify a value

E X^ PHAS }

Phas X!*X^ ]

Adjust the pixel phase to the
specified value for the active
input.

Increment value

E + PHAS }

Phas X!*X^ ]

Increase the pixel phase.

Decrement value

E − PHAS }

Phas X!*X^ ]

Decrease the pixel phase.

View

E PHAS }

X^ ]

Show the pixel phase.

Total pixels (available only for RGB and YUVp input signals)
Specify a value

E X& TPIX }

Tpix X!*X& ]

Adjust the total pixels to the
specified value for the active
input.

Increment value

E + TPIX }

Tpix X!*X& ]

Increase the total pixels.

Decrement value

E − TPIX }

Tpix X!*X& ]

Decrease the total pixels.

View

E TPIX }

X& ]

Show the total pixels.

Active pixels
Specify a value

E X* APIX }

Apix X!*X* ]

Adjust the active pixels to the
specified value for the active
input.

Increment value

E + APIX }

Apix X!*X* ]

Increase the active pixels.

Decrement value

E − APIX }

Apix X!*X* ]

Decrease the active pixels.

View

E APIX }

X* ]

Show the active pixels.

Active lines
Specify a value

E X( ALIN }

Alin X!*X( ]

Adjust the active lines to the
specified value for the active
input.

Increment value

E + ALIN }

Alin X!*X( ]

Increase the active lines.

Decrement value

E − ALIN }

Alin X!*X( ]

Decrease the active lines.

View

E ALIN }

X( ]

Show the active lines.

3:2 film mode detect
Enable

E X!*1FILM }

Film X!*X1) ]

Enable film mode detection.

Disable

E X!*0FILM }

Film X!*X1) ]

Disable film mode detection.

View setting

E X! FILM }

X1) ]

View setting.

NOTES:

X!

= Input selection

1 through 3 (2 and 3 applicable for EDID only)

X^ = Pixel phase

0 through 31 (default = 16)

X& = Total pixels

±512 of the default value for high resolution video; ±127 for interlaced

X* = Active pixels

±512 of the default value for high resolution video; ±127 for interlaced

X( = Active lines

±256 of the default value

X1)

= Off / On

0 = Off or disable, 1 = On or enable

SME 100 • Remote Communication and Control