Extron Electronics SME 100 User Guide User Manual
Page 22

SME 100 Reset Mode Summary
Mode Activation
Result
Purpose and Notes
Factory Firmwar
e
1
Hold in the recessed Reset
button while applying power
to the unit.
The SME 100 reverts to the factory
default firmware for a single power
cycle.
Booting to this mode twice in a row
deletes all user files; settings (such as
drivers, adjustments, and IP settings)
are set to factory default.
Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.
Reset All IP Settings
4
Hold in the Reset button for
about 6 seconds until the
Power LED blinks twice (once
at 3 seconds, again at 6
seconds). Then, release and
press Reset again within
1 second*.
Mode 4:
•
Enables ARP capability.
•
Sets the IP address back to
factory default (192.168.254.254).
•
Sets the subnet mask address
back to the factory default
(255.255.0.0).
•
Sets the gateway IP address to
the factory default (0.0.0.0).
•
Sets port mapping back to factory
default.
•
Turns DHCP off.
•
The Reset LED on the rear panel
of the unit flashes four times in
succession.
Mode 4 is used to set
IP address information using
ARP and the MAC address.
A "Resetting IP Settings"
message appears on the
LCD display.
Reset to Factory Defaults
5
Hold in the Reset button for
about 9 seconds until the
Power LED blinks three times
(once at 3 seconds, again
at 6 seconds, again at 9
seconds). Then, release and
press Reset again within
1 second*.
Mode 5:
Performs a complete reset to factory
defaults (except the firmware).
•
Does everything mode 4 does.
•
Clears port configurations.
•
Resets all IP options.
•
Clears all user settings.
•
Clears all files from the unit.
•
The Reset LED on the rear panel
of the unit flashes four times in
succession.
Mode 5 is useful when wanting
to start over with configuration
and uploading, and also to
replace events.
"Resetting SME 100" appears
on the LCD display.
NOTE: * = For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
SME 100 • Panels and Cabling
16