SME 100 Reset Mode Summary

Mode Activation

Result

Purpose and Notes

Factory Firmwar

e

1

Hold in the recessed Reset
button while applying power
to the unit.

The SME 100 reverts to the factory
default firmware for a single power
cycle.
Booting to this mode twice in a row
deletes all user files; settings (such as
drivers, adjustments, and IP settings)
are set to factory default.

Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.

Reset All IP Settings

4

Hold in the Reset button for
about 6 seconds until the
Power LED blinks twice (once
at 3 seconds, again at 6
seconds). Then, release and
press Reset again within
1 second*.

Mode 4:

Enables ARP capability.

Sets the IP address back to
factory default (192.168.254.254).

Sets the subnet mask address
back to the factory default
(255.255.0.0).

Sets the gateway IP address to
the factory default (0.0.0.0).

Sets port mapping back to factory
default.

Turns DHCP off.

The Reset LED on the rear panel
of the unit flashes four times in
succession.

Mode 4 is used to set
IP address information using
ARP and the MAC address.

A "Resetting IP Settings"
message appears on the
LCD display.

Reset to Factory Defaults

5

Hold in the Reset button for
about 9 seconds until the
Power LED blinks three times
(once at 3 seconds, again
at 6 seconds, again at 9
seconds). Then, release and
press Reset again within
1 second*.

Mode 5:
Performs a complete reset to factory
defaults (except the firmware).

Does everything mode 4 does.

Clears port configurations.

Resets all IP options.

Clears all user settings.

Clears all files from the unit.

The Reset LED on the rear panel
of the unit flashes four times in
succession.

Mode 5 is useful when wanting
to start over with configuration
and uploading, and also to
replace events.

"Resetting SME 100" appears
on the LCD display.