X11$
=
IP address:
xxx.xxx.xxx.xxx
Leading zeros are optional and are suppressed in returned values.
Factory default IP address:
192.168.254.254
Factory default gateway IP address:
0.0.0.0
Factory default DNS server IP address:
0.0.0.0
Factory default multicast IP address:
239.199.188.138
Valid multicast IP addresses:
225.0.0.0
through
239.255.255.255
X11*
=
Hardware MAC address:
00-05-A6-xx-xx-xx
X11(
=
Subnet mask:
xxx.xxx.xxx.xxx
Leading zeros are optional and are suppressed in returned values.
Factory default subnet mask:
255.255.0.0
X12@
=
Verbose / response mode
NOTE: If tagged responses are enabled, all commands will return the
constant string and the data, similar to the response received when
setting a value. Example: the command E CN } returns Ipn • X11@ ]
as a response.
0 = Clear / none (default for telnet connections)
1 = Verbose mode (default for RS-232 host control)
2 = Tagged responses for queries
3 = Verbose mode and tagged responses for queries
X12%
=
Baud rate: 300, 600, 1200, 1800, 2400, 4800, 9600 (default), 19200, 38400,
57600, 115200
X12^
=
Parity:
Odd, Even, None (default), Mark, Space
Only use the
first letter.
X12&
=
Data bits: 7, 8 (default)
X12*
=
Stop bits: 1 (default), 2
X12(
=
Port type
0 = RS-232 (default)
X13)
=
Flow control:
Software, None (default)
Only use the
first letter.
X13!
=
Data pacing (specified in milliseconds (ms) between bytes): 0 through 1000
Default = 0 ms
For host ports, this value is ignored and will always return 0.
X13#
=
Password (up to 12 characters)
All readable characters are permitted except "/", "\", "
|
", and "*".
No blank characters (spaces) can be used in the password.
Passwords are case sensitive.
NOTES:
•
An administrator password must be set before assigning user
passwords. If an administrator password has not first been set, the
E14
error will be returned.
•
If the administrator password is removed, all user created profiles
and passwords are disabled.
SME 100 • Remote Communication and Control
131