X13$
=
Daylight savings time
0 = Off (ignore)
1 = U.S.A.
2 = Europe
3 = Brazil
X14!
=
Check password
The actual password is not shown.
If a password is set, four asterisks (****) are returned.
If a password is not set, nothing is returned.
X14(
=
Default name: shows the default name of the unit using the model name and
the last three pairs of the MAC address.
Example:
SME-100-HD/SD-00-02-3D
X15@
=
Connection security level
NOTES:
•
The response is returned as two digits.
•
A leading zero is used for values lower than 10.
00 = Anonymous
01-10 = Extended security levels (1 through 10)
11 = User (viewer)
12 = Administrator
X16(
=
IP connection timeout: 1 through 65000 (default = 30 = 300 seconds)
NOTES:
•
Applicable to Ethernet connections only.
•
The selected number multiplied by 10 determines the number of
seconds required for a connection timeout.
•
If no data is received during the connection timeout period, the
Ethernet connection is closed.
•
The response is returned as five digits with leading zeros.
•
Connection timeouts can be set on the RS-232 port when using
the global timeout commands only. Using the current port timeout
commands returns the
E13
error.
X18!
=
Text (up to 64 characters)