Sis commands, see, Auto-image – Extron Electronics SME 100 User Guide User Manual
Page 140
Command
ASCII Command
(host to unit)
Response
(unit to host)
Additional Description
Auto-image
Enable
X!*1A
Img X!*1 ]
Turn on auto-image for input
X!.
Disable
X!*0A
Img X!*0 ]
Turn off auto-image for input
X!.
Execute
A
Img ]
Execute auto-image for the
selected input.
Execute and fill
1*A
Img1 ]
Execute auto-image for the
selected input and fill the entire
output.
Execute and follow
2*A
Img2 ]
Execute auto-image for the
selected input and follow the
aspect ratio of the input.
View
X! A
X1) ]
View the auto-image setting.
Horizontal start
Specify a value
E X$ HSRT }
Hsrt X!*X$ ]
Set the horizontal location of
the first active pixel for the
active input.
Increment value
E + HSRT }
Hsrt X!*X$ ]
Increase the value.
Decrement value
E − HSRT }
Hsrt X!*X$ ]
Decrease the value.
View
E HSRT }
X$ ]
Show the horizontal location
of the first active pixel for the
active input.
Vertical start
Specify a value
E X$ VSRT }
Vsrt X!*X$ ]
Set the vertical location of the
first active line for the active
input.
Increment value
E + VSRT }
Vsrt X!*X$ ]
Increase the value.
Decrement value
E − VSRT }
Vsrt X!*X$ ]
Decrease the value.
View
E VSRT }
X$ ]
Show the vertical location of
the first active line for the active
input.
NOTES:
X! = Input selection
1 through 3 (2 and 3 applicable for EDID only)
X$
= Horizontal / Vertical start:
0 through 255 (default midpoint 128 is default value in the input lookup tables)
X1)
=
Off / On
0 = Off or disable, 1 = On or enable
SME 100 • Remote Communication and Control