Creating a Custom EDID

Use the following procedure to create a custom EDID using the Advanced Settings page on
the SME 100 (see figure 82).

Figure 82.

Advanced Settings Page — Creating a Custom EDID

1.

Connect a video output device to the 15-pin HD buffered loop connector (buffered
input 2) or the DVI buffered loop connector (buffered input 3) located on the rear panel
of the SME 100 (see the "

Rear Panel Features

" section on page 12).

2.

Use the

Select Input

radio buttons to select the desired input (buffered input 2 or

buffered input 3) to capture EDID from.

3.

From the

Resolution

drop-down menu, select a custom EDID number to store the

new display EDID.

NOTES:

Custom 1, 2, and 3 capture EDID from the 15-pin HD buffered loop connector.
Custom 4, 5, and 6 capture EDID from the DVI buffered loop connector.

The new EDID will overwrite existing custom EDID information.

If a custom EDID is not captured, the resolution and refresh rate defaults to
1024x768 @ 60 Hz.

4.

Click the

Save Current EDID

button to store the EDID to the custom location.

SME 100 • Web-based Configuration Page