3.

Press and hold the Next button and the Input 3 button simultaneously for approximately
three seconds. This changes the

View Comm Settings

menu to the

Edit Comm

Settings

menu.

4.

Press the Next button repeatedly to cycle to the IP address (

IP

), subnet mask (

SM

), and

default gateway (

GM

) submenus (see figure 25).

Next

Next

Next

Next

Next

+

Input 3

Next

Next

EDIT COMM

SETTINGS

DHCP MODE

ON

SERIAL PORT

9600 RS232

I

P

VIEW COMM

SETTINGS

Change Value
Valid addresses
are 0 – 254.

DHCP Mode
Turn DHCP
on or off.

Select
Octet

S

M

G 000.000.

M 000.000

Change Value
Valid addresses
are 0 – 255.

Select
Octet

Change Value
Valid addresses
are 0 – 254.

Select
Octet

255.255.

000.000

192.168.

254.254

Baud Rates

300 600

1200 1800,

2400 4800 9600 (default),

19200 38400 57600 115200

Figure 25.

Edit Comm Settings Submenus

5.

Change the IP address, subnet mask, and default gateway as necessary. To configure
the addresses:

Cycle to the desired octet by rotating the left Adjust knob (

[

).

Adjust the value of the octet by rotating the right Adjust knob (

{

).

6.

Save the network settings by pressing the Menu button. The network settings of the
SME 100 are now configured.

After the network settings have been saved, the SME 100 can be further configured using
the following methods:

Front panel configuration — For information on configuring the SME 100 using the
front panel, see the "

Front Panel Operation

" section on page 22.

Web-based user interface configuration — For information on configuring the
SME 100 using the web-based user interface, see the "

Web-based User Interface

Operation

" section on page 46.