Installing the software
1.
Use the file browser on the PC to navigate to the executable software file and
double-click it to open it.
2.
Follow the instructions on the Installation Wizard screens to install the software to the
computer.
Running DataViewer
1.
From the desktop, select
Start > All Programs > Extron Electronics >
IPL Tools > DataViewer > Dataviewer
. If a shortcut to DataViewer was placed on
the desktop, the software can be opened by double-clicking on the icon.
2.
The DataViewer Communication Setup window opens (see figure 94).
NOTE: If the Communication Setup window does not appear, select
File >
Connect
from the menu bar.
Sending commands using a TCP/IP connection
1.
Configure the network settings of a control PC so that it can be connected to the
same network as the SME 100. Use an RJ-45 cable to connect the control PC to the
network.
2.
Open DataViewer (see "
3.
On the Communication Setup window (see figure 94):
Figure 94.
TCP/IP Communication Setup Window
a.
Select the
TCP/IP
tab.
b.
Enter the IP address of the SME 100 into the
Hostname / IP Address
field.
c.
In the
Telnet Port
field, enter the port number for the connection.
NOTE: The default port to send SIS commands to the SME 100 is port 23.
d.
Click
OK
. The Communication Setup window closes.
SME 100 • Remote Communication and Control