267 of 310
Register Name:
BSIM
Register Description:
BERT Status Interrupt Mask Register
Register Address:
110Fh + (10h x (n - 1)) + (2000h x [(n - 1) / 8]): where n = 1 to 16
Bit
# 7 6 5 4 3 2 1 0
Name — BBED
BBCO
BECO
BRA1
BRA0
BRLOS
BSYNC
Default
0 0 0 0 0 0 0 0
Bit 6: BERT Bit Error Detected Event (BBED)
0 = Interrupt masked.
1 = Interrupt enabled.
Bit 5: BERT Bit Counter Overflow Event (BBCO)
0 = Interrupt masked.
1 = Interrupt enabled.
Bit 4: BERT Error Counter Overflow Event (BECO)
0 = Interrupt masked.
1 = Interrupt enabled.
Bit 3: BERT Receive All Ones Condition (BRA1)
0 = Interrupt masked.
1 = Interrupt enabled—interrupts on rising and falling edges.
Bit 2: BERT Receive All Zeros Condition (BRA0)
0 = Interrupt masked.
1 = Interrupt enabled—interrupts on rising and falling edges.
Bit 1: BERT Receive Loss Of Synchronization Condition (BRLOS)
0 = Interrupt masked.
1 = Interrupt enabled—interrupts on rising and falling edges.
Bit 0: BERT in Synchronization Condition (BSYNC)
0 = Interrupt masked.