beautypg.com

5 power-down control, Points on power saving, Power-saving in standby modes – Epson S1C33210 User Manual

Page 76

background image

5 POWER-DOWN CONTROL

A-62

EPSON

S1C33210 PRODUCT PART

5 Power-Down Control

This chapter describes the controls used to reduce power consumption of the device.

Points on power saving

The current consumption of the device varies greatly with the CPU's operation mode, the system clocks used,
and the peripheral circuits operated.

Current consumption

low

high

CPU/BCU

SLEEP

HALT2

Operating

HALT2

HALT(basic)

Operating

System clock

OSC1

OSC1

OSC3

OSC3

OSC3

OSC3 oscillation circuit

OFF

OFF

OFF

ON

ON

ON

Prescaler/peripheral circuit

STOP

RUN

To reduce power consumption of the device, it is important that as many unnecessary circuits as possible be
turned off. In particular, peripheral circuits operating at a fast-clock rate consume a large amount of current, so
design the program so that these circuits are turned off whenever unnecessary.

Power-saving in standby modes

When CPU processing is unnecessary, such as when waiting for an interrupt from key entries or peripheral
circuits, place the device in standby mode to reduce current consumption.

Standby mode

Method to enter the mode

Circuits/functions stopped

Basic HALT mode Execute the halt instruction after setting

HLT2OP (D3)/Clock option register
(0x40190) to "0".
When the #BUSREQ signal is asserted from
an external bus master while SEPD (D1)/Bus
control register (0x4812E) = "1".

CPU and DMA

HALT2 mode

Execute the halt instruction after setting
HLT2OP to "1".

CPU, BCU, bus clock, and DMA

SLEEP mode

Execute the slp instruction.

CPU, BCU, bus clock, DMA, high-speed
(OSC3) oscillation circuit, prescaler, and
peripheral circuits that use the prescaler
output clocks

HLT2OP (D3)/Clock option register (0x40190) that is used to select a HALT mode is set to "0" (basic HALT
mode) at initial reset.

Notes: • In systems in which DRAM is connected directly to the device, the refresh function is turned off

during HALT2 and SLEEP modes.

• The standby mode is cleared by interrupt generation (except for the basic HALT mode, which is

set using an external bus master). Therefore, before entering standby mode, set the related
registers to allow an interrupt to be used to clear the standby mode to be generated.

• When clearing the standby mode with an interrupt from port input, the interrupt operates as a

level interrupt regardless of the interrupt trigger setting. When edge trigger is set for the interrupt
trigger, attention must be paid to the port level during standby mode.

The low-speed (OSC1) oscillation circuit and clock timer continue operating even during SLEEP mode. If they
are unnecessary, these circuits can also be turned off.

Function

Control bit

"1"

"0"

Default

Low-speed (OSC1) oscillation ON/OFF control

SOSC1(D0)/

Power control register(0x40180)

ON

OFF