III PERIPHERAL BLOCK: 8-BIT PROGRAMMABLE TIMERS

S1C33210 FUNCTION PART

EPSON

B-III-3-3

8-bit programmable timer 2
• Clock supply to the Ch.0 serial interface

When using the Ch.0 serial interface in the clock-synchronized master mode or the internal clock-based
asynchronous mode, the output clock derived from the underflow signal of the 8-bit programmable timer 2
by dividing it by 2 is supplied to the serial interface as its operating clock. This enables the transfer rate of
the serial interface to be programmed.
To use this function, write "0" to the serial interface control bit SSCK0 (D2) / Serial I/F Ch.0 control
register (0x401E3) to select the internal clock.

8-bit programmable timer 3
• Clock supply to the Ch.1 serial interface

The output clock derived from the underflow signal of the 8-bit programmable timer 3 by dividing it by 2
is supplied to the serial interface as its operating clock. This enables the transfer rate of the serial interface
to be programmed.
Always write "0" to to the serial interface control bit SSCK1 (D2) / Serial I/F Ch.1 control register
(0x401E8) to select the internal clock.

8-bit programmable timer 4

• Clock supply to the Ch.2 serial interface

When using the Ch.2 serial interface in the clock-synchronized master mode or the internal clock-based
asynchronous mode, the output clock derived from the underflow signal of the 8-bit programmable timer 4
by dividing it by 2 is supplied to the serial interface as its operating clock. This enables the transfer rate of
the serial interface to be programmed.
To use this function, write "0" to the serial interface control bit SSCK2 (D2) / Serial I/F Ch.2 control
register (0x401F3) to select the internal clock.

8-bit programmable timer 5
• Clock supply to the Ch.3 serial interface

The output clock derived from the underflow signal of the 8-bit programmable timer 5 by dividing it by 2
is supplied to the serial interface as its operating clock. This enables the transfer rate of the serial interface
to be programmed.
Always write "0" to the serial interface control bit SSCK3 (D2) / Serial I/F Ch.3 control register (0x401F8)
to select the internal clock.