HEIDENHAIN TNC 306 Technical Manual User Manual
Page 71

3–56
TNC 416/TNC 406/TNC 306
PLC inputs/outputs
3/99
PLC outputs
Assignment of the grouped power supply:
Terminal
Assignment
X9
0 V
X10
+24V PL supply and "Control is operational"
X11
+24 V Supply
O32 - O39
X12
+24 V Supply
O40 - O47
X13
+24 V Supply
O48 - O55
X14
+24 V Supply
O56 - O62
X7
X8
Pin number
Assignment
Pin number
Assignment
1
O32
1
O48
2
O33
2
O49
3
O34
3
O50
4
O35
4
O51
5
O36
5
O52
6
O37
6
O53
7
O38
7
O54
8
O39
8
O55
9
O40
9
O56
10
O41
10
O57
11
O42
11
O58
12
O43
12
O59
13
O44
13
O60
14
O45
14
O61
15
O46
15
O62
16
O47
16
"Control is operational"
The analog inputs (X15 to X22) of the PL 410 cannot be evaluated in the LE 360 C! The PLC outputs
are powered in groups and are therefore switched off via EMERGENCY STOP in groups.
Danger to internal components!
Connect inductive loads only with a quenching diode parallel to the inductance.