beautypg.com

Cycles, Cycle inhibit, 7 cycles – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 186: 1 cycle inhibit

background image


4-86

TNC 406/TNC 306

6 Display and operation 4

3/97

6.7 Cycles

The HEIDENHAIN contouring controls permit calling HEIDENHAIN standard-cycles within the NC
program (e.g. pecking, tapping, pocket milling etc.).

In addition, the manufacturer of the machine can program manufacturer-cycles and store them in
the control (see "OEM-cycles"). The sequence of some cycles can be altered by machine parameters
and PLC-markers.

6.7.1 Cycle inhibit

Machine parameter MP7245 can be used to selectively inhibit the HEIDENHAIN standard-cycles.

MP7245.0

Inhibit Cycles 1 to 15
Input range: 0 to 65 535

MP7245.1

Inhibit cycles 16 to 30
Input range: 0 to 65 535

Cycle 1

+ 0 = enable
+ 2 = inhibit

Cycle 2

+ 0 = enable
+ 4 = inhibit

Cycle 3

+ 0 = enable
+ 8 = inhibit

Cycle 4

+ 0 = enable
+ 16 = inhibit

Cycle 5

+ 0 = enable
+ 32 = inhibit

Cycle 6

+ 0 = enable
+ 64 = inhibit

Cycle 7

+ 0 = enable
+ 128 = inhibit

Cycle 8

+ 0 = enable
+ 256 = inhibit

Cycle 9

+ 0 = enable
+ 512 = inhibit

Cycle 10

+ 0 = enable
+ 1024 = inhibit

Cycle 11

+ 0 = enable
+ 2048 = inhibit

Cycle 12

+ 0 = enable
+ 4096 = inhibit

Cycle 13

+ 0 = enable
+ 8192 = inhibit

Cycle 14

+ 0 = enable
+ 16 384 = inhibit

Cycle 15

+ 0 = enable
+ 32 768 = inhibit

Cycle 16

+ 0 = enable
+ 2 = inhibit

Cycle 17

+ 0 = enable
+ 4 = inhibit

Cycle 18

+ 0 = enable
+ 8 = inhibit

Cycle 19

+ 0 = enable
+ 16 = inhibit

Cycle 20

+ 0 = enable
+ 32 = inhibit

Cycle 21

+ 0 = enable
+ 64 = inhibit

Cycle 22

+ 0 = enable
+ 128 = inhibit

Cycle 23

+ 0 = enable
+ 256 = inhibit

Cycle 24

+ 0 = enable
+ 512 = inhibit

Cycle 25

+ 0 = enable
+ 1024 = inhibit

Cycle 26

+ 0 = enable
+ 2048 = inhibit

Cycle 27

+ 0 = enable
+ 4096 = inhibit

Cycle 28

+ 0 = enable
+ 8192 = inhibit

Cycle 29

+ 0 = enable
+ 16 384 = inhibit

Cycle 30

+ 0 = enable
+ 32 768 = inhibit

This manual is related to the following products: