Cycles, Cycle inhibit, 7 cycles – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 186: 1 cycle inhibit

4-86
TNC 406/TNC 306
6 Display and operation 4
3/97
6.7 Cycles
The HEIDENHAIN contouring controls permit calling HEIDENHAIN standard-cycles within the NC
program (e.g. pecking, tapping, pocket milling etc.).
In addition, the manufacturer of the machine can program manufacturer-cycles and store them in
the control (see "OEM-cycles"). The sequence of some cycles can be altered by machine parameters
and PLC-markers.
6.7.1 Cycle inhibit
Machine parameter MP7245 can be used to selectively inhibit the HEIDENHAIN standard-cycles.
MP7245.0
Inhibit Cycles 1 to 15
Input range: 0 to 65 535
MP7245.1
Inhibit cycles 16 to 30
Input range: 0 to 65 535
Cycle 1
+ 0 = enable
+ 2 = inhibit
Cycle 2
+ 0 = enable
+ 4 = inhibit
Cycle 3
+ 0 = enable
+ 8 = inhibit
Cycle 4
+ 0 = enable
+ 16 = inhibit
Cycle 5
+ 0 = enable
+ 32 = inhibit
Cycle 6
+ 0 = enable
+ 64 = inhibit
Cycle 7
+ 0 = enable
+ 128 = inhibit
Cycle 8
+ 0 = enable
+ 256 = inhibit
Cycle 9
+ 0 = enable
+ 512 = inhibit
Cycle 10
+ 0 = enable
+ 1024 = inhibit
Cycle 11
+ 0 = enable
+ 2048 = inhibit
Cycle 12
+ 0 = enable
+ 4096 = inhibit
Cycle 13
+ 0 = enable
+ 8192 = inhibit
Cycle 14
+ 0 = enable
+ 16 384 = inhibit
Cycle 15
+ 0 = enable
+ 32 768 = inhibit
Cycle 16
+ 0 = enable
+ 2 = inhibit
Cycle 17
+ 0 = enable
+ 4 = inhibit
Cycle 18
+ 0 = enable
+ 8 = inhibit
Cycle 19
+ 0 = enable
+ 16 = inhibit
Cycle 20
+ 0 = enable
+ 32 = inhibit
Cycle 21
+ 0 = enable
+ 64 = inhibit
Cycle 22
+ 0 = enable
+ 128 = inhibit
Cycle 23
+ 0 = enable
+ 256 = inhibit
Cycle 24
+ 0 = enable
+ 512 = inhibit
Cycle 25
+ 0 = enable
+ 1024 = inhibit
Cycle 26
+ 0 = enable
+ 2048 = inhibit
Cycle 27
+ 0 = enable
+ 4096 = inhibit
Cycle 28
+ 0 = enable
+ 8192 = inhibit
Cycle 29
+ 0 = enable
+ 16 384 = inhibit
Cycle 30
+ 0 = enable
+ 32 768 = inhibit