HEIDENHAIN TNC 306 Technical Manual User Manual
Page 263

3/2000
TNC 416/TNC 406/TNC 306
List of machine parameters
5-15
Machine
parameter
Function and input
Change
via
Reaction
Page
MP2052
Advanced switch-on distance for reapproach;
After timing (M2780=1), the oscillator signal of the
generator can be switch on earlier. In this way the
control receives a correct analog gap signal during
the transition from positioning to gap control.
Entry range: 0 to 2 [mm]
–
MP2060
Infeed rate when eroding on (M36) and marker
M2620 is set
Entry range: 1 to 500 [mm/min]
Removed in TNC 406 as of software 280 620-07.
If the function is needed for special applications,
you can use MP2081=1 to realize a two-position
control without characteristic curve. An other
possibility: The threshold for free-run feed rate
from MP2141 can be defined with W520 (0..500).
123
4–60
MP2070
Feed rate at maximum gap voltage (5V) and
MP 2020 = 1 and MP 2030 = 1;
Calibration of input characteristic
Entry range: 1 to 3000 [mm/min]
4–57
MP2080
Gap signal input
Entry range: 0 to 2
0 =
Not inverted
1 =
Inverted
2 =
Analog input from spindle potentiometer
(for testing purposes only)
4–56
MP2081
Selection of gap control
Entry range: 0 or 1
0 = Analog input is velocity signal
1 = Analog input is gap signal
–
MP2090
Speed for a non-controlled rotary axis (M3/M4)
Entry range: 1 to 100 [rpm]
123
4-54
MP2100
Editing possible in defined positions of eroding
table
Entry value: 0 to 255
–
MP2110
Delay of "spark-out is completed" signal (marker
M2616)
Entry range: 0.1 to 99.9 [s]
123