9.2 RS 422/V.11 data interface

The RS-422/V.11 data interface is only integrated in the logic unit LE 416 and LE 406. It is
designated to control the generator.

If used correctly, the RS-422/V.11 serial data interface will ensure error-free data transmission up to
a distance of 1000 m between logic unit and peripheral unit.

The connection to the peripheral unit is made via a cable adapter which is attached to either the
operating console or the control cabinet. See also under the heading "Mounting dimensions" and
“Cable Overview”.

The cable adapter Id.-Nr. 249 819 01 is connected to the logic unit with the HEIDENHAIN
connecting cable Id.-Nr. 250 478 ..

LE416/LE 406 X22

Connecting Cable

Id. Nr. 289 208 ..

Adapter Block

Id. Nr. 311 086 01

D-sub

terminal

(female)

15-pin

Assignment

D-sub

connector

(male)

15-pin

D-sub

connector

(female)

15-pin

D-sub

terminal

(male)

15-pin

D-sub

terminal

(female)

15-pin

1

Chassis GND

1

Black

External

shield

1

1

1

2

RXD

2

Blue

2

2

2

3

CTS

3

Gray

3

3

3

4

TXD

4

White

4

4

4

5

RTS

5

Green

5

5

5

6

DSR

6

White/Green

6

6

6

7

DTR

7

Green/Pink

7

7

7

8

Signal GND

8

Black

8

8

8

9

RXD

9

Red

9

9

9

10

CTS

10

Pink

10

10

10

11

TXD

11

Brown

11

11

11

12

RTS

12

Yellow

12

12

12

13

DSR

13

Brown/Green

13

13

13

14

DTR

14

Red/Blue

14

14

14

15

Do not assign

15

Violet

15

15

15

Housing

External

shield

Housing

Housing

Housing

Housing

The interfaces complies with the recommendations in IEC 742 EN 50 178 for separation
from line power.

The following cable type must be used for the connection to the peripheral unit:
LIYCY 7 x 2 x 0.14 Cu