Rs 422/v.11 data interface – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 59

3–44
TNC 416/TNC 406/TNC 306
Data interface
3/99
9.2 RS 422/V.11 data interface
The RS-422/V.11 data interface is only integrated in the logic unit LE 416 and LE 406. It is
designated to control the generator.
If used correctly, the RS-422/V.11 serial data interface will ensure error-free data transmission up to
a distance of 1000 m between logic unit and peripheral unit.
The connection to the peripheral unit is made via a cable adapter which is attached to either the
operating console or the control cabinet. See also under the heading "Mounting dimensions" and
“Cable Overview”.
The cable adapter Id.-Nr. 249 819 01 is connected to the logic unit with the HEIDENHAIN
connecting cable Id.-Nr. 250 478 ..
LE416/LE 406 X22
Connecting Cable
Id. Nr. 289 208 ..
Adapter Block
Id. Nr. 311 086 01
D-sub
terminal
(female)
15-pin
Assignment
D-sub
connector
(male)
15-pin
D-sub
connector
(female)
15-pin
D-sub
terminal
(male)
15-pin
D-sub
terminal
(female)
15-pin
1
Chassis GND
1
Black
External
shield
1
1
1
2
RXD
2
Blue
2
2
2
3
CTS
3
Gray
3
3
3
4
TXD
4
White
4
4
4
5
RTS
5
Green
5
5
5
6
DSR
6
White/Green
6
6
6
7
DTR
7
Green/Pink
7
7
7
8
Signal GND
8
Black
8
8
8
9
RXD
9
Red
9
9
9
10
CTS
10
Pink
10
10
10
11
TXD
11
Brown
11
11
11
12
RTS
12
Yellow
12
12
12
13
DSR
13
Brown/Green
13
13
13
14
DTR
14
Red/Blue
14
14
14
15
Do not assign
15
Violet
15
15
15
Housing
External
shield
Housing
Housing
Housing
Housing
The interfaces complies with the recommendations in IEC 742 EN 50 178 for separation
from line power.
The following cable type must be used for the connection to the peripheral unit:
LIYCY 7 x 2 x 0.14 Cu