beautypg.com

Data transfer plc, Nc and nc → plc, 3 data transfer plc → nc and nc → plc – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 305

background image


3/2000

TNC 416/TNC 406/TNC 306

Program creation

7-15

B0 to B127

Freely available, not deleted with RESET

B128 to B255

Freely available, deleted with RESET

B256 to B511

Data transfer NC → PLC

B512 to B767

Data transfer PLC → NC

B768 to B1023

Machine parameters → PLC

2.3

Data transfer PLC

NC and NC PLC

PLC

NC

The Q parameters Q100 to Q107 transfer numbers from the PLC to the part program. This means
that Q100 to Q107 can be overwritten by the PLC. The numerical value is registered in Double word
D528 and the Q parameter numbers 0 to 7 are defined in Word W516. The numbers 0 to 7
correspond to parameters Q100 to Q107. The transfer is activated with the strobe marker M2713,
which must be set with the next M/S/T strobe.

Marker

Function

Set

Reset

M2713

Activate the transfer of the value from D528
to the Q-Parameter defined in W516

PLC

NC

Address

Function

D 528

Double word with multiple function, here data for transfer from the
PLC to the NC

W516

Q-Parameter No. for numerical transfer from PLC to NC
(0 – 7 = Q100 – Q107)

NC

PLC

Various machine parameters are reserved for data transfer in the PLC. These machine parameters
are kept in the Double words D768 to D956 and the Words W960 to W974 and W976 to W1006.
PLC-positioning, datum-shifts, feed rates for PLC-positioning or coding for the release of certain
PLC-functions etc. can be filed in these machine parameters. The eroding parameters are still
available, which, depending on whether they are defined as Q parameters in the NC program or with
a table, are transferred by the NC or E-table into the PLC. The evaluation of all numerical values
transferred to the PLC takes place in the PLC program. (See chapter "Machine integration", section
"Eroding parameters.")

Address

Function

D768

Value from MP4210.0

D772

Value from MP4210.1

D776

Value from MP4210.2

D780

Value from MP4210.3

D784

Value from MP4210.4

D788

Value from MP4210.5

This manual is related to the following products: