Probing, Display and programming, 7 probing – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 267: 8 display and programming

3/2000
TNC 416/TNC 406/TNC 306
List of machine parameters
5-19
3.7 Probing
Machine
parameter
Function and input
Change
via
Reaction
Page
MP6100
Successive probing
Entry range: 1 to 5
4-114
MP6110
Maximum difference of probe values during
successive probing
Entry range: 0 to 2 [mm]
4-114
MP6120
Probing feed rate
Entry range: 1 to 30.000 [mm/min]
123
4-113
MP6130
Maximum measuring range
Entry range: 0 to 30.000 [mm]
123
4-114
MP6140
Retraction path
Entry range: 0 to 30 000 [mm]
4-114
MP6150
Retraction feed rate in probing cycle
Entry range: 1 to 30 000 [mm/min]
123
4-113
3.8 Display and programming
Machine
parameter
Function and input
Change
via
Reaction
Page
MP7210
Programming station
Entry values: 0, 1, 2
0 = Control
1 = Programming station: PLC active
2 = Programming station: PLC inactive
123
RESET
4-89
MP7212 *)
Acknowledgment of „Power interrupted“
Entry values: 0 or 1
0 = „Power interrupted“ must be acknowledged
with CE key
1 = automatically acknowledged after 3 sec
MP7230
Dialog language
Entry values: 0 to 3
Software Nr.:
286 180/
286 181/
286 182/
280 620
280 621
280 622
0 = English
English
English
1 = German
German
German
2 = French
Swedish
Czech
3 = Italian
Finnish
Reserved
123
–
MP7231
OEM label
Entry values: 0 to 99
0 = standard label
1 to 99 = number of PLC error message,
displayed as OEM label
–