beautypg.com

7 eroding, Parameters, 7 eroding parameters – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 162

background image


4-62

TNC 406/TNC 306

4 Gap control

3/97

The following examples for TNC 306 show how the flushing timer may be written in the PLC
program:

L

W676

; Auto Jump Distance (AJD)

X

K + 100

=

D730

L

W678

; Eroding time (ER)

X

K + 100

=

D734

L

M2621

; Request flushing

R

M2621

L

M910

; Flushing on buffer marker

A[
L

D734

; Eroding time

>

K + 0

]
CMT

31

EM
LBL

31

;Timer Module

L

D212

; Timer Buffer

>

K + 0

JPT

32

L

D734

; Eroding Timer

=

D212

LBL

32

L

D212

-

K + 40

:PLC Cycle Time

=

D212

<=

K + 0

S

M2621

; Request Flushing

EM

4.7 Eroding parameters

In order to control the generator as required, the TNC stores appropriate data as eroding parameters.
Machine parameters MP2199 defined whether these eroding parameters are stored as Q-
parameters in the NC program or in the form of erosion tables.

MP2199 Enable erosion tables

0 = Tables not active
2 = Tables active

This manual is related to the following products: