7 offset adjustment, 8 adjusting the monitoring functions – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 247

2/97
TNC 406/TNC 306
15 Commissioning and start-up procedure
4-147
15.3.7 Offset adjustment
The rough offset adjustment has already been carried out on the servo amplifier. The offset
adjustment possibility described in the section "Servo positioning" lets a fine offset adjustment be
performed.
15.3.8 Adjusting the monitoring functions
The following entry values are recommended for the monitoring functions (see section "Servo
positioning"):
Machine parameter
Function
Entry value
MP1710
Position monitoring
1.2
× lag in rapid traverse
MP1720
Position monitoring (EMERGENCY
STOP)
1.4
× lag in rapid traverse
MP1140
Movement monitoring
0.5 [V]
MP1030
Positioning window
0.005 [mm]
MP1110
Standstill monitoring
0.1 [mm]
If the drives of the machine permit narrower limits, these may be entered.