beautypg.com

Status display and graphics depiction, 9 status display and graphics depiction – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 270

background image


5-22

TNC 416/TNC 406/TNC 306

List of machine parameters

3/2000

Machine
parameter

Function and input

Change
via

Reaction

Page

MP7290.0-5

Display step The finest resolution is 1/10 µm.
Entry values: 0 to 6

Value of MP

Resolution of display

µm

inch

0

0.1 µm

0.00001

1

0.5 µm

0.00002

2

1 µm

0.0001

3

5 µm

0.0002

4

10 µm

0.001

5

50 µm

0.002

6

100 µm

0.01

3.9 Status display and graphics depiction

Machine
parameter

Function and input

Change
via

Reaction

Page

MP7300

Cancel program data and status display with M02,
M30 and end of program
Entry values: %xxx
Bit0

0=Do not cancel status display
1=Delete program data and display
status with PGM END or M02, M30
which means that it functions like a
program selection or the reset soft key

Bit 1

1=Do not delete Q parameters when
program is selected or reset soft key is
pressed

Bit 2

1=Do not delete tool data and Q
parameters when program is selected or
reset soft key is pressed.

The Q parameters are always deleted after power
interruption, and the tool data are always retained.

123

4-84

MP7305

GOTO to a CYCL CALL in mode program run
is permitted
Entry values: 0 or 1
0 =

GOTO permitted

1 =

GOTO not permitted

This manual is related to the following products: