Status display and graphics depiction, 9 status display and graphics depiction – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 270

5-22
TNC 416/TNC 406/TNC 306
List of machine parameters
3/2000
Machine
parameter
Function and input
Change
via
Reaction
Page
MP7290.0-5
Display step The finest resolution is 1/10 µm.
Entry values: 0 to 6
Value of MP
Resolution of display
µm
inch
0
0.1 µm
0.00001
1
0.5 µm
0.00002
2
1 µm
0.0001
3
5 µm
0.0002
4
10 µm
0.001
5
50 µm
0.002
6
100 µm
0.01
3.9 Status display and graphics depiction
Machine
parameter
Function and input
Change
via
Reaction
Page
MP7300
Cancel program data and status display with M02,
M30 and end of program
Entry values: %xxx
Bit0
0=Do not cancel status display
1=Delete program data and display
status with PGM END or M02, M30
which means that it functions like a
program selection or the reset soft key
Bit 1
1=Do not delete Q parameters when
program is selected or reset soft key is
pressed
Bit 2
1=Do not delete tool data and Q
parameters when program is selected or
reset soft key is pressed.
The Q parameters are always deleted after power
interruption, and the tool data are always retained.
123
4-84
MP7305
GOTO to a CYCL CALL in mode program run
is permitted
Entry values: 0 or 1
0 =
GOTO permitted
1 =
GOTO not permitted
–