3/2000

TNC 416/TNC 406/TNC 306

PLC-functions

7-5

1 PLC-functions

The integrated PLC in the TNC 406 and TNC 306 contains its own text editor for creating the list of
instructions for the PLC-program. Commands and comments are entered via the ASCII-keyboard on
the control panel of the TNC 406 or the keyboard of the TNC 306 (see Section "Programming and
editing-files").

The functions TRACE and TABLE, as well as a syntax check on entering the PLC commands and a
logical test with the Function COMPILE can make it easier to find faults in the PLC-program (see
section "Test functions").

8 ms are available for a PLC-run. Up to 4000 logic commands, equivalent to 32 Kbytes, can be
processed within this period (executable memory). A new PLC-run commences every 40 ms/20 ms
(depending on MP1700), i.e. every 40 ms/20 ms the inputs are read and outputs are set.

The following section shows how to start PLC-operation.

1.1

Selecting PLC-operation

PLC-operation covers all functions for creating and testing the PLC-programs.

It can be selected as follows, using code number 807 667.

Select NC operating-mode
"Programming and editing"

Press MOD

key

TNC 306: Enter code number 807 667

NC 406: Press soft key „key code“

and enter code number 807 667

TNC 306: ENT key

PLC-operation is selected

(Main menu)

PLC-operation can be stopped by pressing END

.