Bit commands, 1 bit set (bs, bsx) – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 374

7-84
TNC 416/TNC 406/TNC 306
Commands
3/2000
3.10 Bit commands
3.10.1 BIT SET (BS, BSX)
BS
Abbreviation for PLC Editor:
BS (BIT SET)
Byte/Word/Double
Constant
Execution time [µs]
2.0 to 2.4
2.0
Number of bytes
6
8
Operands: B, W, D, K, X
Operation:
With this command, each bit in the Accumulator can be acted on. The addressed bit is set to "1"
through the use of the BS command. The selection (addressing) of the corresponding bit is derived
from the content of the specified Operand or a Constant. In the bit-numbering, bit 0 corresponds to
the LSB and bit 31 the MSB. For operand contents larger than 32, the operand value Modulo 32 is
used, i.e. the integer remainder from the division (operand value)/32.
Example:
Load Double word D8 in the Accumulator, set the bit 0 of the Accumulator to "1" and store the result
in Double word D12.
Initial state:
Double word D8 = 3E 80 (hex)
Double word D12 = ?
Accumulator and operand contents are shown here in hexadecimal notation.
Line Instruction
Accumulator content
Operand content
xx
xx
xx
xx
1
L D8
00
00
3E
80
00
00
3E
80
2
BS K+0
00
00
3E
81
3
= D12
00
00
3E
81
00
00
3E
81
Line 1:
Load Double word D8 into the Accumulator.
Line 2:
The bit specified in the operand is set to 1.
Line 3:
The result is stored in Double word D12.