beautypg.com

Less than (<), 2 less than (<) – HEIDENHAIN TNC 306 Technical Manual User Manual

Page 353

background image


3/2000

TNC 416/TNC 406/TNC 306

Commands

7-63

3.5.2 LESS THAN (<)

<

Abbreviation for the PLC-Editor:

< (LESS THAN)

Byte/Word/Double

Constant

Execution time [µs]

1.8 to 2.4

2.0

Number of bytes

6

8

Operands: B, W, D, K

Operation:
With this command, a direct transfer from Word to Logic processing occurs. The contents of the
Word Accumulator are compared with the contents of the addressed operand. If the Word
Accumulator is smaller than the operand, the condition is true and the Logic Accumulator is set to 1.
If the Word Accumulator is smaller or equal to the operand, the Logic Accumulator is set to 0. The
comparison takes place over the number of bits in the operand, i.e. B = 8 bit, W = 16 bit and
D = K = 32 bit.

Example:
A constant is to be compared with the contents of Double word D8. The result is then assigned to
Marker M500.

Initial state:

Constant

= 16 000

Double word D8 = 15 000

The Accumulator and operand contents are shown in decimal notation. The 10 bit wide Accumulator
allows the entry of the highest possible Accumulator contents (2 147 483 647).

Line Instruction

Accumulator contents

Operand contents

x

x x x

x x x

x x x

1

L K16000

1 6

0 0 0

Bit

31

.

.

.

7

0

1

< D8

... x x x x x x 0 x x x x x x x

1 5

0 0 0

2

= M500

... x x x x x x 0 x x x x x x x

0

Line 1:

The constant is loaded into the Accumulator

Line 2:

The contents of the Accumulator and the Operand are compared
(Accumulator < Operand ?).
As the condition is not fulfilled the Logic Accumulator is set to 0.

Line 3:

The contents of the Logic Accumulator (The result of the comparison) are
assigned to Marker M500.