7 visual display unit (vdu), Connector assignment, 7 visual disp lay unit (vdu) – HEIDENHAIN TNC 306 Technical Manual User Manual
Page 52: 1 connector assignment

3/99
TNC 416/TNC 406/TNC 306
Visual display unit (VDU)
3–37
7 Visual disp lay unit (VDU)
The LE 406 is prepared for connecting the BC 110 CRT screen, the LE 306C for connecting the BE
212 CRT screen or BF 110 flat luminescent screen. The status is indicated by the Id.-Nr. on the ID
label (Id.-Nr. 270 641 for BE 212 and Id.-Nr. 270 642 for BF 110).
7.1 Connector assignment
X9 Visual display unit BE 212 and BF 110
X43 Visual display unit BC 110
Flange socket with female insert
Pin number
BE 212
BF 110
BC 110
BC 120
1
0 V power supply
–
GND
R
2
+12 V power supply
–
Not used
G
3
Not used
Not used
Not used
B
4
+12 V power supply
Not used
Do not use
5
Not used
Not used
Not used
Do not use
6
Not used
Not used
Not used
GND
7
–
Video
R
GND
8
0 V power supply
GND
GND
9
V SYNC
V SYNC
V SYNC
Do not use
10
H SYNC1
–
H SYNC1
GND
11
–
0 V Signal
GND
GND
12
0 V Signal
–
Not used
Do not use
13
Video
–
Not used
HSYNC
14
H SYNC 2
G
VSYNC
15
CLOCK
B
Do not use
Housing
Outer shield = Unit housing